ZL-60C Fluorescent Penetrant
ZL-60C is a water-washable fluorescent penetrant. After washing and drying, penetrant bleeds out of discontinuities and indications glow yellow-green under UV-A light.
Key facts
| Type | Fluorescent, water-washable (AMS 2644 Type 1, Method A) |
|---|---|
| Sensitivity | Level 2 |
| Excess removal | Water wash; SKC-S on a cloth can be used in field work |
| Developer | Used without developer: indications bleed out and are inspected under UV-A |
| Part number | 0218040 (aerosol), 0218040-10L, 0218040-20L |
| Packaging | 400 ml aerosol, cartons of 10; 10 L and 20 L containers |
| Contaminants | Batch certificate of sulfur and halogen content on request |
| Shelf life | 24 months from manufacture; batch number and dates on every pack |
| Label standards | AMS 2644 · ASTM E1417/E1417M · EN ISO 3452-2 (as printed on the label) |
How to use it
- Clean and dry the area.
- Apply ZL-60C evenly and leave it for the dwell time in your procedure.
- Wash off excess penetrant with water, checking under UV-A light. ASME Section V (T-673.1) limits the water pressure and temperature.
- Dry the surface; penetrant held in cracks bleeds out to the surface.
- Inspect in a darkened area: UV-A of at least 1000 µW/cm² at the surface, ambient light no more than 21.5 lx, and at least 5 minutes of dark adaptation (ASME Section V, T-676.4).
ASME Section V (T-675) requires a developer; omitting it is allowed by agreement between the contracting parties under SE-165 (4.1, Note 2). Always follow your written procedure.
Follow your approved written procedure. Final sensitivity depends on surface condition, discontinuity type, dwell time, excess-penetrant removal, developer thickness, temperature, lighting and operator technique.
In use

Fluorescent penetrant inspection under UV-A light. Photo: Senior Airman Tiffany Trojca, public domain, via Wikimedia Commons. 
Penetrant inspection during aircraft maintenance. Photo: U.S. Navy Photo by Photographer’s Mate 2nd Class John Collins., public domain, via Wikimedia Commons. 
Weld quality inspection in a fabrication shop. Photo: Trice Denny, public domain, via Wikimedia Commons.
Other products for liquid penetrant testing (PT)
Buying in Iran? ZL-60C is manufactured under license and sold by KimiaNDT.